Lining Condensate Tank

The condensate tank base had lost its integrity, corrosion has damaged the floor due to water forming under the condensate, and being in direct contact with the steel, once the epoxy paint lining was damaged.

Processing took place in the following steps:

  1. Corroded steel tank base and 1st course shell were grit blasted to SA 2.5 cleanliness and to a minimum 75µm profile.
  2. A Zink Primer was spray applied to the blasted area.
  3. Polyurea QuickSpray @ 2.5mm applied with Graco XP-2 high pressure spray units.
  4. All inlet high abrasion areas were sprayed @ 5mm to provide extra protection.

Failure to attend to the corrosion problem would have caused the tank to condemn. To offer a similar rigid epoxy as previously applied meant this would cracked due to movement of the tank base causing premature failure again.

VIP Polyurea was specified as a long term protection system with flexibility.

The complete process of surface-preparation and application of base coat was successfully completed in 10 days despite extreme HS regulations and conditions of spraying internally.

Reference details


Project description

Lining of the condensate tank

City

Sharjah

Country

United Arab Emirates

Size (in m²)

2400 m²

Year

2011

Customer

BP / Petrofac

Applicator

Anticor LLC, Dubai

Consultant

AMCE Inspection Group


Used products
Vip Kontakt Icon

Questions?

We are looking forward to your message.
We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.